Key takeaways
- Winterize before the first hard freeze. Near Detroit the median first 32°F night is October 29 and the first 28°F night November 8.
- Water left in the system can crack PVC, rupture poly pipe and crack the brass body of the backflow, according to Hunter Industries.
- A compressed-air blowout is held to about 50 psi (Hunter allows up to 80 psi on PVC), two minutes or so per zone, with eye protection.
- Hunter and Rain Bird both say a qualified professional is the safer choice. Before plow season, mark heads along the driveway too.
On this page
When should you blow out sprinklers in Michigan?
Before the first hard freeze. MSU Extension's fall checklist says to blow out or winterize an irrigation system before a hard freeze, and Hunter Industries says the same: before the first freeze, anywhere frost reaches deeper than the pipe.
In Macomb County that points to late October through early November. From NOAA's daily records at Detroit Metro Airport for the falls of 1996 to 2025:
| Fall milestone near Detroit | Median date | What it means for sprinklers |
|---|---|---|
| First 32°F low | October 29 | Shallow parts start to be at risk; finish watering |
| First 28°F hard freeze | November 8 | MSU's deadline; the system should be empty |
| First snow of 2 inches or more | December 12 | Heads along the driveway are now hidden |
Medians, so half of falls are earlier. Book a blowout early enough that a mid-October cold snap does not catch the system full.
What happens if you don't winterize?
Water expands when it freezes. Hunter Industries explains what that does to each part of a system:
- PVC pipe (the rigid white kind) can crack, even when the system was drained, because some water always stays behind.
- Polyethylene pipe (the flexible black kind common in cold climates) stretches more but can still rupture.
- The backflow device, usually the brass assembly near the house, has internal parts that freezing water damages, and the brass body itself can crack.
None of this shows in winter. It shows in spring, as a geyser at a fitting, a soggy patch over a split line or a backflow that leaks when the water comes on.
Leaves still down?
We do fall cleanups near our snow routes: leaves off the lawn and out of the beds, perennials cut back and a final mow. Quoted after a look at the yard.
How are sprinkler systems winterized?
There are three approaches, and which one applies depends on how the system was installed.
| Method | How it works | Who it suits |
|---|---|---|
| Manual drain | Shut off the water, open drain valves at the low points and drain the supply side | Only systems built with drains at every end and low point |
| Automatic drain | Spring-loaded valves drain the lines each time the system shuts off | Systems built with them; check for stuck-open drains (puddling) |
| Compressed-air blowout | An air compressor pushes the water out of each zone | Most systems; Hunter's default if you do not know your type |
Summarized from the Rain Bird and Hunter Industries winterizing guides.
What does a blowout involve?
Knowing the steps helps you judge whoever does it. In outline, from the Rain Bird and Hunter instructions:
- Shut off the irrigation water supply.
- Connect the compressor after the backflow device. Air is never blown through the backflow itself, and flow sensors come out first.
- Open a zone before any air goes in, starting with the zone farthest from the compressor or highest in elevation.
- Keep the pressure low. Rain Bird says not to exceed 50 psi. Hunter's limits are 50 psi for poly pipe and 80 psi for PVC, and never above the weakest part's rating.
- Run each zone about two minutes, then move on. Two or three short cycles per zone beat one long one, because air rushing through dry pipe builds heat that can warp fittings and damage rotor seals.
- Stop when only a fine mist comes out of the heads.
- Release the pressure, drain the backflow and leave its valves and test cocks as the manufacturer specifies. Leave the controller in the off position.
Should you do it yourself?
For most homeowners, no. Both manufacturers say so directly: Hunter says it is best to call a professional because of the dangers involved, and Rain Bird says to contact one if you lack the equipment or have any doubt. The reasons are practical. A blowout needs a compressor with a high air-flow rating: Rain Bird recommends a large 50- to 70-gallon unit, and Hunter sizes it from the flow of the largest zone. Filling a small tank and dumping it into the line to make up the difference is exactly what Hunter tells you not to do. Compressed air also throws debris, and both guides require eye protection and staying clear of heads and valves.
Hire a qualified irrigation contractor and ask what pressure they use, whether they remove flow sensors and how they handle the backflow. We do no irrigation or sprinkler work ourselves.
Before plow season: mark the heads by the driveway
A sprinkler head a few inches off the driveway edge is invisible under snow and sits right where a plow blade or a shovel lands. While the system is being winterized:
- Mark heads near pavement with a driveway stake or a short marker so they show above snow. Driveway markers and snow stakes covers spacing and height.
- Tell your snow company where they are. Buried fixtures are exactly what stop notes are for: our crews see what you tell us about them on every visit.
- Walk the rest of the edge for hoses, lights and decorations. The full list is in getting your yard ready for snow plowing and the before-the-first-snow checklist.
Sources
- MSU Extension: fall yard and garden cleanup tips (2022) — once growth stops, lower the mower no more than one notch, about half an inch; winterize irrigation before a hard freeze
- Hunter Industries: winterizing your irrigation system — freeze damage to pipe and backflow; 50 psi poly, 80 psi PVC; best done by a professional
- Rain Bird: fall is blow-out season, tips for winterizing your sprinkler system (2025) — 50 psi, no more than 2 minutes per zone, eye protection
- NOAA Regional Climate Centers, ACIS daily records for Detroit Metro Airport (DTW), falls of 1996 to 2025; our count of the first 32°F and 28°F lows each fall